TIS Instruments (S) Pte Ltd

Multi-Function Calibrator  > MARTEL MC-1200

High Accuracy Multi-Function Calibrator

The Martel MC-1200 Multi-Function Calibrator provides
a feature set unmatched in high accuracy, hand-held
calibrators in its price range. The MC-1200 Calibrator
provides the functions and accuracy associated with
fixed-installation, laboratory instruments, and has
everything needed for virtually any calibration task.
Measure and source thermocouples, RTDs, current,
voltage, and frequency, and source pulse trains.

A communications port compatible with Fluke® 700
Series, Mensor®, and Martel pressure modules is
provided, as is an isolated mA/V read-back circuit.
Arrow keys, direct numeric keypad entry, and three
software-driven function buttons, plus a large backlit,
menu-driven graphics display combine to provide a
highly intuitive, simple yet powerful operator interface.

Built-in 250 Ohm resistor for Hart™ compatibility,
compatibility with smart transmitters and PLCs, full
fuseless protection, and a serial communications port
for full control with ASCII commands, are just some of
the additional features that make the MC-1200 the
single, most indispensable tool available for virtually
any calibration task. The MC-1200 is supplied in a
tough, rubber boot; a carrying case is also available as
an option.

       COMMON FEATURES
>>   Measure and source T/Cs (13 types), RTDs (13
       types), Ohms, current, voltage, frequency; source
       pulse trains  

>>   Isolated mA/V read-back circuit for complete
       transmitter calibration  

>>   Pressure module communication port compatible with
       Fluke 700 Series, Mensor, and Martel pressure
       modules  

>>   Built-in 24 V supply can drive 4 – 20 mA loops up to
       1000 Ohms

>>   Direct entry of custom RTD coefficients(RO, A, B, C)  

>>   All source modes can be programmed with
       dedicated setpoints to speed calibration and
       linearity tests  

>>   Highest accuracy in class to 0.015% of reading  

>>   Meets CE requirements and is designed to IEC
       1010 safety standard

>>   Fluke, Mensor, and Martel Pressure Modules

General Specifications:
Voltage Read and
Source:

Source
0.000 to 20.000 VDC
Read
Isolated 0.000 to 30.000 VDC
Non-isolated 0.000 to 20.000 VDC

Thermocouple mV:
Read and Source
-10.000 to +75.000 mV
Current (mA):
Source
0.000 to 24.000 mA
Read
Isolated 0.000 to 24.000 mA
 Non-isolated 0.000 to 24.000 mA

Frequency (1 to 20
V selectable
amplitude):

CPM Source and Read
2.0 to 600.0 CPM
Hz Source and Read
1.0 to 1000.0 Hz
kHz Source and Read
1.0 to 10.00 kHz
Pulse (Source only;
1 to 20V selectable
amplitude):

Pulses
1 to 30,000.0  
  2 CPM to 10 kHz  

Ohms:
Source
Read

5.0 to 4000 Ohms
0.00 to 4000.0 Ohms

Thermocouple
Read and Source:

J Thermocouple
K Thermocouple
T Thermocouple
E Thermocouple
R Thermocouple
S Thermocouple
B Thermocouple
C Thermocouple
XK Thermocouple
BP Thermocouple
L Thermocouple
U Thermocouple
N Thermocouple

200.0 to +1200.0 °C
-200.0 to +1370.0 °C
-200.0 to +400.0 °C
-200.0 to +950.0 °C
-20.0 to +1750.0 °C
-20.0 to +1750.0 °C
+600.0 to +1800.0 °C
0 to +2316.0 °C
-200.0 to +800.0 °C
0 to +2500.0 °C
-200.0 to +900.0 °C
-200.0 to +400.0 °C
-200.0 to +1300.0 °C

RTD Read and
Source:

Ni120 (672)
Pt100 (385)
Pt100 (3926)
Pt100 (3916)
Pt200 (385)
Pt500 (385)
Pt1000 (385)
Cu10
YSI400
Cu50  
Cu100
Pt385
Pt385-50

-80.0 to +260.0 °C
-200.0 to +800.0 °C
-200.0 to +630.0 °C
-200.0 to +630.0 °C
-200.0 to +630.0 °C
-200.0 to +630.0 °C
-200.0 to +630.0 °C
-100.0 to +260.0 °C
+15.00 to +50.00 °C
-180 to +200 °C  
-180 to +200 °C
-200 to +800.0 °C
-200 to +800.0 °C

Environmental:
Operating Temperature
-10°C to +50°C
Storage Temperature
-20°C to +70°C
Stability
±0.005% of reading/°C outside of 23
°C ±5°C

Power Requirements
6 VDC; Batteries 4x AA; alkaline or
optional rechargeable

Physical (includes
rubber boot)

Dimensions 8.7"H x 4.2"W x 2.3"D
(220.9 x 106.6 x 58.4 mm)
Weight 30.5 ounces (863 gms)

Accessories Included
Test leads, 4-AA alkaline batteries,
NIST Certificate, and instruction
manual

Optional Accessories
Carrying Case, Model CC572
Accuracy:
Voltage2
±0.015% of reading, ±2 mV
Thermocouple
mV ±0.02% of reading, ±10 µV
Thermocouple Errors
(in °C; add 0.2 for Cold
Junction
Compensation error

RTD Read and Source
  Type J           0.2 °C
  Type K         
 0.3°C
  Type T          
0.2 °C
  Type E         
 0.2 °C
  Type R        
 1.2 °C
  Type S        
 1.2 °C
  Type B       
  1.2 °C
  Type C        
0.6°C
  Type XK      
0.2 °C
  Type BP     
 0.9°C
  Type L        
 0.2 °C
  Type U       
 0.25 °C
  Type N       
 0.4°C
  Ni120 (672)           0.2 °C
  Pt100 (385)           0.2 °C
  Pt100 (3926)         0.2 °C
  Pt100 (3916)         0.2 °C
  Pt200 (385)            0.8°C
  Pt500 (385)            0.4°C
  Pt1000 (385)          0.2 °C
  Cu10                        1.4°C
  YSI400                     0.1°C
  Cu50                        0.4°C
  CU100                     0.3°C
  Pt385-10                 1.4°C
  Pt385-50                 0.4°C
RTD IEX-range:
  Read
Source
Current
(mA)

±0.015% of
reading, ±2 µA

±0.015% of reading,
±2 µA

CPM
±0.05% of
reading

±1 LSD ±0.05% of
reading

Hz
±0.05% of
reading

±1 LSD ±0.05% of
reading

kHz
±0.05% of
reading

±1 LSD ±0.125% of
reading

Ohms
400 Ohm Range

±0.025% of
reading, ±0.05 Ω

±0.025% of reading,
±0.05 Ω

4000 Ohm Range
±0.025% of
reading, ±0.5 Ω

±0.025% of reading,
±0.5 Ω

Click on the following link for the product specification.   
Martel MC-1200

Test & Instrument Services

Email: sales@tisinstruments.com
Tel: +65 6779 9272  Fax: +65 6873 8262

Crystal Engineering

Budenberg

General Resistance

Martel

Tek-Know

TIS

Mensor