TIS Instruments (S) Pte Ltd
Automatic Pneumatic Pressure
Calibrator
APC150
Reduces Calibration Time by 40%

On-Line Pressure Regulation compensate for Ambient Temperature Effect

Pressure Control Stability to 0.01% Full Scale

Accuracy of 0.025% Full Scale (Optional 0.01% Full Scale)

Execute 10 Points Test on a –99.9 to 1000 kpa Transmitter in Minutes!!!

Temperature Compensated from 0 to 50 Deg C

4 Engineering Units

Built-in Internal Servo Pump

Standard Range –90 to 1000 Kpa (Multi-range: 50, 200, 1000 kpa)

Vacuum to –99.9 kPa with optional external vacuum pump

Include PC Calibration Software as standard


Specifications___________________

Accuracy Range: 0.025% Full Scale (optional 0.01% Full Scale)

Optional Range: -90 to 50, -90 to 200, -90 to 1000 kPa

Optional Range:-99.9 to 50, -99.9 to 200, -99.9 to 1000kPa

Control Stability: 0.01% of Full Scale

Stability Time: less than 15 seconds.

Pressure Resolution: 5 or 6 Digits depending on range.

Engineering Unit: kPa, Psi, Kg/cm2,Bar, Mpa (depend on range)

Pressure connection: 1/8” and ¼” NPT Female

Medial Compatibility:Air Display:¼ VGA Monochrome Display (320x240 pixels)

Electrical Input: 4-20 Milli-amp with 24 Vdc Loop Power.

Accuracy: 0.025% Full Scale + 1 LSD

Resolution: 0.001 Milliamp
(Optional HP34401A DMM, Resolution 0.001 Ma)

Power Supply: Internal Built-in Lead-Acid Battery with Charger

Battery Usage: 8 hours after fully charge

Unit Size: Pelica Hard Case , 35x28x12 cm (LxWxH)

Weight: 10 kg

Note: Accuracy Statement include: Linearity, Hystersis, Drift and Temperature Range from 0-50
Deg C Recommended Re-Calibration of the equipment for a period of 1 year.


___Ordering Information_______________

Range: APC-150: -90 to 1000kPa, -90 to 200kPa, -90 to 100kPa, -90 to50 kPa

Range: APC-150: -99.9 to 1000kPa, -99.9 to 200kPa, -99.9 to 100kPa, -99.9 to50
kPa
(-99.9 kPa require optional external vacuum pump)

* Contact Factory for other ranges

Each Unit Include :1)Power Cord
                           2)Factory Calibration Certificate
                           3)Operating Manual
                           4)Tubing / Fittings
                               (1/4”, 3/8” & ½” NPT Female)
                           5) Test Leads,
                               RS232 communication wire
                           6) 220 Vac Charger
                           7) PC Window-based Calibration S/W