| TIS Instruments (S) Pte Ltd |
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
| Automatic Pneumatic Pressure Calibrator APC300 |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
| Reduces Calibration Time by 40% On-Line Pressure Regulation compensate for Ambient Temperature effect Pressure Control Stability to 0.01% Full Scale Accuracy of 0.025% full Scale (Optional 0.01% Full Scale) Execute 10 Points Test on a 2000 kpa Transmitter in Minutes!!! Temperature Compensated from 0 to 50 Deg C Built-in Micro-Stepping Pump, do not require external gas 4 Engineering Units Standard Range -90 to 2000 kpa Include PC Calibration Software as standard Specifications____________________ Accuracy Single Range: 0.025% Full Scale (optional 0.01% Full Scale) Optional Single Range: -90 to 100, -90 to 200, -90 to 1000 and -90 to 2000 kpa Resolution: 5 to 6 Digits depending on Range Control Stability: 0.01% of Full Scale Stability Time: less than 15 seconds Engineering unit: Psi, Kpa, Kg/cm², Bar, mmH2O Pressure Connection: 1/8" and 1/4" NPT Female Medial Compatibility: Clean Dry Air Display: 1/4 VGA Display (320x240 pixels) Electrical input: 4-20 Milli-amp with Loop Power Accuracy: 0.05% Full Scale + 1 LSD Resolution: 0.01 Milliamp (Optional HP34401A DMM, Resolution 0.001 Ma) Power Supply: 230 Vac @ 50/60Hz, 4Amp Unit Size: 280x180x420 mm (<1000kPa), 280x180x540 mm (>1000kPa) Weight: 12 Kg (<1000kPa), 17 Kg (>1000kPa or <2000kPa) Note: Accuracy Statement include: Linearity, Hystersis, Drift and Temperature Range from 0-50 Deg C Recommended Re-Calibration of the equipment for a period of 1 year. __Ordering Information___________ Range: APC-300: -90 to 2000 kPa, (-99.9 kParequire optional external vacuum pump) Contact Factory for other ranges Each Unit Include: 1)Power Cord 2)Calibration Certificate 3)Operating Manual 4)Tubing / Fittings (1/4”, 3/8”, ½” NPT Female) 5) Test Leads, RS232 communication cable 6) PC Window-Based Calibration SoftwareTIS |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
| Click on the following link for the product specification. AHC SERIES - Automatic Pneumatic Pressure Calibrator |
|||||||||||||||||||||||||||||||||||||||||||||
